timer auto drain valve function 99 hours
Tonhe A 20-S Series
Timer Controlled shut off Valve
Application
l Water meter , water leak detection system and water treatment etc equipment
l HAV and fire works. Automatic drain system
l Irrigation ect small control equipment
ADD:No.1012 Xincheng Road, Huangyan, Taizhou, Zhejiang, China
EMAIL: tonhe08@china-tonhe.com
Mobile:+86-18957612187
Skype:meizi2661
Technical Parameters:
Product size |
□NPT/BSP1/4” 3/8” 1/2"' □NPT/BSP 3/4'' □NPT/BSP 1" |
Maximum working pressure |
1.0 MPa |
Circulation medium |
Fluid, air |
Valve open /closed time |
≤ 7 seconds |
Rated voltage |
□AC/DC9-24V □AC110-230V (Optional ) |
Setting valve open time |
Any time in 0-24H |
Setting valve closed time |
Any time in 0-24H |
Working current |
≤500MA |
Stall current setting |
0-599mA |
Life time |
100000 times |
Valve Body material |
□Brass □Nickel plated Brass □304 Stainless steel (Optional) |
Actuator material |
Engineering Plastics |
Sealing material |
EPDM & PTFE |
Actuator rotation |
90° |
Max. torque force |
4N.M |
Cable Length |
0.5m,1.5m(Optional) |
Environment temperature |
-15℃~50℃ |
Liquid temperature |
2℃~90℃ |
Manual override |
No |
Indicator |
Yes |
Protection class |
IP67 |
1 Parameter specifies
Working voltage :AC110-230V/AC/DC9-24V
Setting valve open time : any time in 0-24H
Setting valve close time : any time in 0-24H
Valve close automatic in case of power is failure
2 Timer specification
3 Operation instruction
Actuator parameter setting have two menu structures on below:
Function code ( fist menu),
The setting parameters of function code ( secondary menu)
Picture 0 Secondary menu operation menu
Function code |
Content |
Value |
Unit |
Remarks |
t on |
|
00:00:00 – 99:59:59 |
H:M:S |
|
toFF |
valve keeping closed time |
00:00:00 – 99:59:59 |
H:M:S |
|
PonS |
Power -on Action |
On/oFF |
|
|
Prot |
Stall current setting |
0-599 |
MA |
When the current is bigger than the setting value 1.6S, the motor will stop working , and the display will show Err. |
Parameter function control table
4 Stalling protection function
When the actuator is detected stalling, it will run in reverse direction .when reach to the open or closed position , and do the close or open action again , meanwell displaying flashed 0000-0001 on screen ( indicating the current retrying times ) . If it fail at third retrying , the valve will stop running and display ERRL on the screen .